Repellent systems
Systems for water treatment with polyphosphate salts. Economic, effective and simple solution to avoid calcium deposits and magnesium. Inhibit the formation of incrustations of calcium without changing the hardness of the water. Effective in removing existing deposits and as a protective coating for pipes, heat exchangers, boilers and water heaters.
Lavatrix - salt dispenser polyphosphate crystals for washing machine
Filter 2 pieces (head and pot), complete with polyphosphate salt crystals.
- Head: reinforced polypropylene.
- Pot: SAN transparent.
- Treating material: Salt polyphosphate crystals.
- Applications: protection and anti-corrosion for domestic installations.
- Home Use: protection and anti-corrosion washers.
- For technical use.
- Use only in a vertical position.
- Output: 3/4
- Size: H 130 x W 70 mm
specifications
- Maintenance: No
- Average duration: 6 months ≃
- Maximum working temperature: 35 ° C (95 ° F)
- Total water hardness: max 50 ° f (500 ppm CaCO3)
- Maximum working pressure: 7 bar (101.5 psi)
- Max temperature of exercises: or 45 ° C (113 ° F)
- Min Operating Temperature: 5 ° C (41 ° F)
- Flow-load indication: 70 l / min (3 bar)